Re: USG Recovery Procedure
Thank you for the image file !!The file was was a little bigger then the original 4GB USB disk within the gateway. Nevertheless, I wrote the file to the original usb stick and started up. Everything...
View ArticleRe: Switch ERL against Edgerouter Pro?
will work fine. If you're using ssh, it's best to load a basic config first (i.e. run one of the setup wizards) and stick eth0, 1, or 2 in the same subnet as the corresponding interface from the ERL...
View ArticleRe: Forwarding EdgeRouter/EdgeSwitch Syslog to Microsoft OMS
Yup, if it's raw syslog, it's just text data. It's not hard to install packages ... but you're limited on space (and CPU and RAM) on an ER. You would (likely) be better off sending the ER syslog to a...
View ArticleRe: Updated Google Fiber + EdgeRouter Lite / PoE IPv4 & IPv6 config.boot and...
Right. The TV boxes have to be connected directly to the Network + box, either through the RG6 or one of the LAN ports.
View ArticleRe: Edgerouter Lite Dual DHCP WAN, not getting IP after disconnect
What your trying to do isn't wrong but there's an easier/better way of doing it now. I would update to the latest firmware and use the load balance wizard.But if you want to know whats going wrong with...
View ArticleRe: VRRP Failover sometimes doesn't failover all groups
Shouldn't you put both interfaces in the same group to begin with?
View ArticleRe: Pixelated VOD IPTV
Find one temp solution to solve this issue:Change the port speed from 1G to 100M.Then the UDP packet loss issue does not exist. Tested on V1.9.1.This method should also work on other versions.(Please...
View ArticleRe: Firewalling OpenVPN Site-to-Site
Does anyone have any ideas what is happening? It seems like the traffic is not registering as coming through the tunnel, but in that case, what where would it be coming through?
View ArticleRe: Forwarding EdgeRouter/EdgeSwitch Syslog to Microsoft OMS
Hi -Yea - I'm thinking about installing a SCOM server locally and using that to forward the syslogs. I looked at doing nagios but as I am not a Linux guru I don't think I will be able to manage it well...
View ArticleRe: EP-R6 loadbalancing 2 AF5X Link + VLAN possible???
Hi The problem with lacp is that the links are half duplex and the switch need to use fullduplex 100 or 1000. What do you think if the AFX5 with duty cycle 50% reaches a bandwidth of 119mbit, so...
View ArticleRe: TOP SITES ADULT
You'll need to be running I believe at least version 1.8.5 so you can enable traffic analysis (also known as DPI).You create a firewall rule with the direction in for your vlan or interface you want...
View ArticleRe: TOP SITES ADULT
There is a walkthrough on the web to do everything I described, if I can find it I'll try to post that link as well. It's been some time since I came across it.
View ArticleRe: Forwarding EdgeRouter/EdgeSwitch Syslog to Microsoft OMS
I use nagios myself. Figured learning something was desirable to being beholden to "someone else" (especially given the "oh, our backups weren't working")
View ArticleRe: Firewalling OpenVPN Site-to-Site
You said you changed addresses to 10.10.10.x but did you actually define that as the subnet for the VPN?
View ArticleRe: DNS problem
ballama wrote: eth0 : LAN (192.168.1.1/24)eth3 : WAN (192.168.0.1 to ADSL router) System name server : 127.0.0.1 Change your system name server to something other than itself -- 8.8.8.8 for example....
View ArticleRe: Firewalling OpenVPN Site-to-Site
Not sure about this but maybe try option topology subnet too?
View ArticleRe: EdgeOS Traffic Analysis Counter resetting!
Traffic Analysis data is discarded after roughly 30 minutes, if you search the forums you'll see that's the official word from the UBNT folks with no ETA on extending that time frame. Definitely go...
View ArticleRe: DNS problem
, please post your configuration so we can see what's going on (using the command show configuration | no-more). There isn't a problem per se with having the router's system DNS be 127.0.0.1 - as long...
View ArticleRe: Wierd issue with redundant EdgeRouter Lite
ARP was the wrong word; FDB? Either way, 4-5 minutes MIGHT not be long enough (I mean, I agree with you, faster is better, but some network designs don't permit that). Check the config of your switch...
View ArticleRe: Connecting two ER8's
This was not my choice, the customer has a standard of a dedicated router per system. These are isolated AV systems that normally do not need to communicate with each other. In this scenario, the...